Monitoring methods for skin dose in interventional radiology
Abstract
Interventional radiology makes an increasing use of X-ray for diagnostic and therapeutic procedures. The dose received by the patient sometime exceeds the threshold value of deterministic effects, and this requires monitoring of the dose delivered to the patients. Delivered dose could be assessed through either direct or indirect methods. The direct methods use dosimeters that are placed on the skin during the procedure, whereas, the indirect methods are based on measured quantities derived from the equipment itself. Each method has its own limitations; however, the main concern is the ability to measure the dose more accurately due to complexity of the anatomical structures of the patient and the variable course of each procedure. This review article summarizes the principle and main advantages and disadvantages of each method. A comparison of the performances of each method for interventional fluoroscopy and radiography in its ability to monitor the patient’s skin dose is provided.
Keywords
Full Text:
PDFReferences
Vano E, Gonzalez L, Fernández JM, Haskal ZJ. Eye lens exposure to radiation in interventional suites: caution is warranted. Radiology 2008; 248:945-53.
Fletcher S W, Kuan H M, Miller D, et al. Techniques to estimate radiation dose to skin during fluoroscopically guided procedures Skin Dose Measurements. AAPM 2002.
Balter S. Methods for measuring fluoroscopic skin dose. Pediatr Radiol 2006; 36:136-40.
Hill R, Healy B, Holloway L, et al. Advances in kilovoltage x-ray beam dosimetry. Phys Med Biol 2014; 59:R183-231.
Meyer P, Regal R, Jung M, et al. Feasibility of a semiconductor dosimeter to monitor skin dose in interventional radiology. Med Phys 2001; 28:2002-6.
Ehringfeld C, Schmid S, Poljanc K, et al. Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV. Phys Med Biol 2005; 50: 289-303.
Peet DJ, Pryor MD. Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagnostic radiology. Brit J Radiol 1999; 72: 562-8.
Cheung T, Buston MJ, Yu PK. MOSFET dosimetry in-vivo at superficial and orthovoltage X-ray energies. Australas Phys Eng Sci Med 2003; 26:82-4.
Bower M W, Hintenlang D E. The characterization of a commercial MOSFET dosimeter system for use in diagnostic X ray. Health Phys 1998; 75: 197-204.
Ehringfeld C, Schmid S, Poljanc K, et al. Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV. Phys Med Biol 2005; 50:289-303.
Hugtenburg RP, Johnston K, Chalmers GJ, Beddoe AH. Application of diamond detectors to the dosimetry of 45 and 100 kvp therapy beams: comparison with a parallel-plate ionization chamber and Monte Carlo. Phys Med Biol 2001; 46:2489-501.
Knoos T, Munck Af, Rosenschold P, Wieslander E. Modelling of an orthovoltage X-ray Therapy Unit with the EGSnrc Monte Carlo package. J Phys 2007: Conf. Ser. 74 021009.
Mandapaka AK, Ghebremedhin A, Patyal B, et al. Evaluation of the dosimetric properties of a synthetic single crystal diamond detector in high energy clinical proton beams. Med Phys 2013; 40:121702.
Heydarian M, Hoban PW, Beddoe AH. A comparison of dosimetry techniques in stereotactic radiosurgery. Phys Med Biol 1996; 41:93-110.
Yin Z, Hugtenburg RP, Green S, Beddoe AH. Dose responses of diamond detectors to monoenergetic x-rays. Nucl Instrum Methods Phys 2004; 213: 646-56.
Ciancaglioni I, Marinelli M, Milani E, et al. Dosimetric characterization of a synthetic single crystal diamond detector in clinical radiation therapy small photon beams. Med Phys 2012; 39:4493-501.
Ding GX, Malcolm AW. An optically stimulated luminescence dosimeter for measuring patient exposure from imaging guidance procedures. Phys Med Biol 2013; 58:5885-97.
Hyer DE, Fisher RF, Hintenlang DE. Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology. Med Phys 2009; 36:1711-6.
Lacroix F, Archambault L, Gingras L, et al. Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications. Med Phys 2008; 35:3682-90.
Yoo WJ, Jeon D, Seo JK, et al. Development of a scintillating fiber-optic dosimeter for measuring the entrance surface dose in diagnostic radiology. Radiat Meas 2013; 48: 29-34.
Yoo WJ, Shin SH, Jeon D, et al. Development of a fiber-optic dosimeter based on modified direct measurement for real-time dosimetry during radiation diagnosis. Meas Sci Technol 2013; 24: 094022.
Podgorsak EB. Radiation oncologyphysics: A handbook for teachers and students. International atomic energy agency. VIENNA, 2005.
Lessard F, Archambault L, Plamondon M, et al. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range. Med Phys 2012; 39:5308-16.
Dong SL, Chu TC, Lan GY, et al. Characterization of high-sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF:Mg,Cu,P thermoluminescence dosimeters for use in diagnostic radiology. Appl Radiat Isot 2002; 57:883-91.
International Atomic Energy Agency. IAEA Report No°457: Dosimetry in diagnostic radiology: an international code of practice. Vienna, 2007.
Akselrod MS, Lucas AC, Pofl JC, Mckeever SWS. Optically stimulated luminescence of Al2O3. Radiation measurement 1998; 29:391-9.
Ding GX, Malcolm AW. An optically stimulated luminescence dosimeter for measuring patient exposure from imaging guidance procedures. Phys Med Biol 2013; 58:5885-97.
Reft CS. The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams. Med Phys 2009; 36:1690-9.
Aznar MC, Andersen CE, Bøtter-Jensen L, et al. Real-time optical-fibre luminescence dosimetry for radiotherapy: physical characteristics and applications in photon beams. Phys Med Biol 2004; 49:1655-69.
Niroomand-Rad A, Blackwell CR, Coursey BM, et al. Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine. Med Phys 1998; 25:2093-115.
McCabe BP, Speidel MA, Pike TL, Van Lysel MS. Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner. Med Phys 2011; 38:1919-30.
International Commission on Radiation Units and Measurements. ICRU Report No° 74: Patient dosimetry for x rays used in medical imaging. Journal of the ICRU 2005; 5 (2).
International Electro technical Commission. IEC 60601: Medical electrical equipment part 2-43: particular requirements for the safety of x-ray equipment for interventional procedures. Geneva: IEC, 2000.
Balter S, Hopewell JW, Miller DL, et al. Fluoroscopically guided interventional procedures: a review of radiation effects on patients' skin and hair. Radiology 2010; 254:326-41.
International Electro technical Commission. IEC 61674: Medical Electrical Equipment- Dosimeters with ionization chambers and/or semi-conductor detectors as used in X ray diagnostic imaging. Geneva: IEC, 2012.
Vañó E, Guibelalde E, Fernández JM, et al. Patient dosimetry in interventional radiology using slow films. Br J Radiol 1997; 70:195-200.
Balter S, Schueler BA, Miller DL, et al. Radiation doses in interventional radiology procedures: the RAD-IR Study. Part III: Dosimetric performance of the interventional fluoroscopy units. J Vasc Interv Radiol 2004; 15:919-26.
Benmakhlouf H, Fransson A, Andreo P. Influence of phantom thickness and material on the backscatter factors for diagnostic x-ray beam dosimetry. Phys Med Biol 2013; 58:247-260.
Johnson PB, Borrego D, Balter S, et al. Skin dose mapping for fluoroscopically guided interventions. Med Phys 2011; 38:5490-9.
Sandblom V, Mai T, Almén A, et al. Evaluation of the impact of a system for real-time visualisation of occupational radiation dose rate during fluoroscopically guided procedures. J Radiol Prot 2013; 33:693-702.
Vano E, Fernandez JM, Sanchez R. Occupational dosimetry in real time. Benefits for interventional radiology. Radiation Measurements 2011; 46: 1262-5.
Bordier C, Klausz R, Desponds L. Patient dose map indications on interventional x-ray systems and validation with GafchromicXR-RV3 film. Radiat Prot Dosimetry 2014; pii: ncu181.
DOI: http://dx.doi.org/10.14319/ijcto.0301.1

This work is licensed under a Creative Commons Attribution 3.0 License.
International Journal of Cancer Therapy and Oncology (ISSN 2330-4049)
© International Journal of Cancer Therapy and Oncology (IJCTO)
To make sure that you can receive messages from us, please add the 'ijcto.org' domain to your e-mail 'safe list'. If you do not receive e-mail in your 'inbox', check your 'bulk mail' or 'junk mail' folders.